Attic ventilation shall not be required when determined not necessary by the code official due to atmospheric or climatic conditions.
2009 irc attic ventilation. It brings together all building plumbing mechanical fuel gas energy and electrical provisions for one and two family residences. The ventilation amount and opening size requirements can be found in section 806 roof ventilation of chapter 8 roof ceiling construction. The total net free ventilating area shall not be less than 1 150 of the area of the space ventilated except that reduction of the total area to 1 300 is permitted provided that at least 50 percent and. For impact rated fenestration complying with section r301 2 1 2 of the irc or section 1608 1 2 of the ibc maximum u factor shall be 0 75 in zone 2 and 0 65 in zone 3.
As well as soil stack vent pipe and chimney flashing shall be applied according to the asphalt shingle manufacturer s. January 2009 code for residential buildings that creates minimum regulations for one and two family dwellings of three stories or less. The majority of the requirements related to attic ventilation have not changed much from the previous editions. The following are the requirements taken directly from the irc.
The example below uses this exception and the calculation is based on a 100 x120 building with a hip roof and 2 overhangs on all sides. Openings in roof framing members shall conform to the requirements of section r802 7. Any increase in the size of the vent shall be made inside the structure a minimum of 1 foot 305 mm below the roof or inside the wall. R806 2 minimum vent area.
Required ventilation openings shall open directly to the outside air. Section r806 4 of the 2009 international residential code irc and section r806 5 of the 2012 irc have requirements for unvented conditioned attic assemblies. Benefits of proper attic ventilation ice dams roof ventilation in the irc 2009 irc code section r806 2 r806 2 minimum area. Also when using a vapor retarder in an attic space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8.
International residential code 2009 irc 2009 chapter 1 scope and administration. Adequate attic ventilation is a long standing requirement in building codes for moisture control. U factor and total ua res check approach. Nrca guidelines regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation.
Where the 97 5 percent value for outside design temperature is 0 f 18 c or less every vent extension through a roof or wall shall be a minimum of 3 inches 76 mm in diameter.